{"product_id":"hkm-740627-12-channel-holter-ecg-monitoring-system-with-24-hour-continuous-recording-and-advanced-analysis-functions","title":"HKM-740627 12-Channel Holter ECG Monitoring System with 24-Hour Continuous Recording and Advanced Analysis Functions","description":"\u003cdiv\u003e\n\u003cp\u003eIntroducing the HKM-740627 12-Channel Holter ECG Monitoring System, an advanced solution for continuous cardiovascular monitoring. This state-of-the-art device is designed to record and analyze ECG waveforms for up to 24 hours, making it ideal for use in both medical institutions and community settings.\n\u003cbr\u003e\n\n\u003cbr\u003e\nEquipped with a 12-lead system that adheres to international standards, this ECG Monitoring System provides real-time data storage, ensuring accurate and reliable monitoring. The system features advanced arrhythmia analysis based on proprietary MCSSTM and TMCATM technologies, which significantly streamlines the workload for healthcare providers.\n\u003cbr\u003e\n\n\u003cbr\u003e\nKey features of the HKM-740627 include:\n\u003cbr\u003e\n\n\u003cbr\u003e\n- Sync analysis for 12-leads to guarantee precise identification of QRS waveforms without distortion.\n\u003cbr\u003e\n- A comprehensive library of over 10 predefined templates, allowing for the differentiation of various pathologic waveforms, such as atrial premature beats and ventricular premature beats.\n\u003cbr\u003e\n- Flexible analysis channel selection, enabling users to choose any channel as the primary focus for analysis.\n\u003cbr\u003e\n- Enhanced atrial fibrillation analysis, offering both AUTO and manual review options to improve accuracy.\n\u003cbr\u003e\n- Robust functionality for pacemaker analysis across all major types, alongside dedicated pacing analysis templates for various conditions.\n\u003cbr\u003e\n- Quick review analysis function, permitting single or full-lead ECG evaluations at any set time interval.\n\u003cbr\u003e\n- Heart rate variability analysis options for 5 minutes, 1 hour, and 24 hours to offer deeper insights into cardiac health.\n\u003cbr\u003e\n- Convenient one-key printing for speedy report generation and effective case management.\n\u003cbr\u003e\n\n\u003cbr\u003e\nIn addition to these capabilities, the HKM-740627 features advanced ST segment analysis to examine abnormal ST changes and assess myocardial ischemia comprehensively. Furthermore, it includes unique analysis functions to predict the risk of sleep breath pause syndrome and to evaluate mortality risk in patients with myocardial infarction. \n\u003cbr\u003e\n\n\u003cbr\u003e\nWith its user-friendly interface and sophisticated analytical capabilities, the HKM-740627 12-Channel Holter ECG Monitoring System represents a significant advancement in cardiac monitoring technology, making it a vital tool for medical professionals dedicated to providing precise and effective patient care.\u003c\/p\u003e\n\u003cp\u003e\n Introduction\n \u003cbr\u003e\n \u003cbr\u003e\n Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.\n \u003cbr\u003e\n \u003cbr\u003e\n Function\n \u003cbr\u003e\n 1)The recorder can real-time store ECG data for 24-hour.\n \u003cbr\u003e\n 2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.\n \u003cbr\u003e\n 3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.\n \u003cbr\u003e\n 4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.\n \u003cbr\u003e\n 5)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.\n \u003cbr\u003e\n 6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO\/manual analysis, more accurate in atrial fibrillation analysis.\n \u003cbr\u003e\n 7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.\n \u003cbr\u003e\n 8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.\n \u003cbr\u003e\n 9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.\n \u003cbr\u003e\n 10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.\n \u003cbr\u003e\n 11)One-key print, convenient and fast to print the reports.\n \u003cbr\u003e\n 12)Perfect case management function.\n \u003cbr\u003e\n 13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help the doctors comprehensively judge myocardial ischemia.\n \u003cbr\u003e\n 14)The risk of sleep breath pause can be predicted by the unique \"Sleep breath pause syndrome\"analysis function.\n \u003cbr\u003e\n 15)The death risk in patients with myocardial infarction can be predicted by the \"HRT\" analysis function.\n \u003cbr\u003e\n 16)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.\n \u003cbr\u003e\n 17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.\n \u003cbr\u003e\n \u003cbr\u003e\n Performance\n \u003cbr\u003e\n Lead: standard 12-lead\n \u003cbr\u003e\n Record time: 24-hour\n \u003cbr\u003e\n Power supply: two “AA” batteries\n \u003cbr\u003e\n Interface: USB2.0\n \u003cbr\u003e\n Sampling accuracy: 24bit\n \u003cbr\u003e\n Sampling frequency: 250Hz\n \u003cbr\u003e\n Dynamic range: 10mV\n \u003cbr\u003e\n Input impedance: ≥10MΩ\n \u003cbr\u003e\n CMR: ≥60dB\n \u003cbr\u003e\n Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%\n \u003cbr\u003e\n Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.\n \u003cbr\u003e\n System noise: ≤50µVp-p\n \u003cbr\u003e\n Multichannel crosstalk: ≤0.2mV\n \u003cbr\u003e\n Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.\n \u003cbr\u003e\n Minimum measure signal: 50 µV\n \u003cbr\u003e\n With the function in the presence of pacemaker pulses\n \u003cbr\u003e\n Timing accuracy: the overall error during 24h shall not exceed 30s.\n \u003cbr\u003e\n \u003cbr\u003e\n Accessories\n \u003cbr\u003e\n Lead cable (1 set)\n \u003cbr\u003e\n ECG electrode (1 bag)\n \u003cbr\u003e\n USB cable(1)\n \u003cbr\u003e\n Bag(1)\n \u003cbr\u003e\n User manual(1)\n \u003cbr\u003e\n \u003cbr\u003e\n Physical characteristic\n \u003cbr\u003e\n Dimension: 111mm(L) × 61mm(W) × 25mm(H)\n \u003cbr\u003e\n Weight: about 105g(without batteries)\n \u003cbr\u003e\n \u003cbr\u003e\n Optional configuration\n \u003cbr\u003e\n Refer to BOM.\n \u003cbr\u003e\n \u003cbr\u003e\n Certification\n \u003cbr\u003e\n CE, FDA\n \u003cbr\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tech \u0026 Electronics \u003e\u003e","offers":[{"title":"- Default","offer_id":43227096023123,"sku":"868053899577","price":504.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0624\/6170\/6323\/files\/HKM-740627-12-Channel-Holter-ECG-Monitoring-System-with-24-Hour-Continuous-Recording-and-Advanced-Analysis-Functions.jpg?v=1766665891","url":"https:\/\/www.hekomart.com\/products\/hkm-740627-12-channel-holter-ecg-monitoring-system-with-24-hour-continuous-recording-and-advanced-analysis-functions","provider":"Hekomart.com","version":"1.0","type":"link"}